GE  DS200TBQBG1ACB  Input Termination Module


Features

 DS200TBQBG1ACB  Input Termination Module
Comprehensive Input Handling: Supports multiple input types, including discrete and analog signals, enabling versatile use in various control systems.
High-Density Terminal Configuration: Designed with a high-density terminal layout, allowing for efficient connection of numerous input signals in a compact space.
Robust and Durable Design: Constructed with industrial-grade materials to withstand harsh operating conditions, ensuring long-term reliability and performance.
Simplified Wiring and Installation: Features clear terminal markings and an organized layout to facilitate easy and error-free wiring during installation.

Seamless Integration: Compatible with a wide range of industrial control systems, providing smooth integration into existing setups with minimal configuration requirements.

Dimensions:28.6x7x4cm

 

Details

DS200TBQBG1ACB is an Input Termination Module developed by GE. It is a part of the Mark V

control system. The Input Termination Module (TBQB) is strategically located at position seven within the R2 and R3

cores of the system. This terminal board serves a critical role in handling and processing

various input signals essential for monitoring and controlling operational parameters.

Connections

1.  The Input Termination Module is strategically positioned within the R2 and R3 cores of the industrial system,

fulfilling a crucial role in the management and processing of essential input signals vital for operational oversight and

control. Located at position seven, this terminal board serves as a central hub for handling a variety of critical signals, including vibrations,

analog currents, voltages, pulse rates, and compressor stall detections. These signals are pivotal in monitoring

the health, performance, and safety of equipment within the operational environment.

2.  One of the primary connections on the board is JGR, which plays a pivotal role in transmitting vibration

signals, as well as analog current and voltage signals, to the board in their respective cores (R2 and R3).

These signals provide invaluable insights into mechanical vibrations and electrical parameters, facilitating real-time monitoring and

proactive maintenance strategies. Such data is essential for ensuring optimal equipment performance and longevity across industrial applications.

3.  Another significant connection, JHR, handles pulse rate inputs and compressor stall detection inputs, directing

them to the TCQC board within their respective cores. Pulse rate inputs offer critical frequency data for operational

adjustments, while compressor stall detection inputs preemptively identify potential risks, enhancing operational safety and

efficiency. This integration of signals across the board and its connections underscores

its role in enabling comprehensive data acquisition and control capabilities.

 

Emailsales@amikon.cn

Skype :miyazheng520

Phone/WhatsApp : 86-18020776792

 

Freequently Asked Questions

What is the primary function of the DS200TBQBG1ACB Input Termination Module?
The DS200TBQBG1ACB is designed to terminate and manage multiple input signals within a control system. It provides a reliable interface for connecting various input devices to the control unit.
What types of input signals does the DS200TBQBG1ACB support?
The DS200TBQBG1ACB supports a range of input signals, including both discrete (digital) and analog signals, making it suitable for a variety of industrial applications.
How is the DS200TBQBG1ACB installed?
The DS200TBQBG1ACB is typically installed in a control cabinet or panel. It features a high-density terminal configuration that simplifies wiring, with clearly marked terminals to ensure correct connections.
What maintenance is required for the DS200TBQBG1ACB?
The DS200TBQBG1ACB requires minimal maintenance. Regular checks for secure terminal connections and cleanliness are recommended to ensure continued reliable operation.

 

More Recommend Items

General Electric UR6TH Multilin Digital I/O Module
General Electric IS200IGPAG2AED Drive Power Supply Board
General Electric IS220PDIAH1AD IS220PDIAH1A Discrete Input Module
General Electric IS220PRTDH1AD IS220PRTDH1A Resistance Temperature Device
General Electric IS420ESWAH1A Mark VIe network switch
General Electric IS420ESWAH3A Mark VIe IONet Switch
General Electric ES5DP33 720007 EntelliPro ES Motor Controller
General Electric DS200RTBAG2A DS200RTBAG2AHC RELAY TERMINAL BOARD
General Electric IS220PPRFH1B PROFIBUS Master Gateway I/O Module
General Electric GS9208/IR2 Infrared Flame Detector
General Electric 269PLUS-D/O-100P-125VDC Control System
General Electric 745-W3-P511-G51-HI-R-E Transformer Protection System
General Electric XMTC-62-11-0 Thermal Conductivity Transmitter
General Electric XMTC-62-21 Thermal Conductivity Transmitter
General Electric XMTC-6C-11 Thermal Conductivity Transmitter

Email : sales@amikon.cn  

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

Quality | Reliability | Integrity

More than 40.000.000 products available and worldwide support

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact